<?xml version="1.0"?>
<Articles JournalTitle="Iranian Journal of Allergy, Asthma and Immunology">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Iranian Journal of Allergy, Asthma and Immunology</JournalTitle>
      <Issn>1735-1502</Issn>
      <Volume>3</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="epublish">
        <Year>2004</Year>
        <Month>09</Month>
        <Day>15</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">The Effect of Recombinant Tissue Plasminogen Activator (r-tPA) on Quantitation of Neutralising Anti-Streptokinase Antibodies</title>
    <FirstPage>121</FirstPage>
    <LastPage>126</LastPage>
    <AuthorList>
      <Author>
        <FirstName></FirstName>
        <LastName>Afshin Afshari  R. Elizbeth Holme</LastName>
        <affiliation locale="en_US"></affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>01</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">The measurement of anti-streptokinase antibodies can distinguish the patients who may benefit from streptokinase and those who should be treated with some other thrombolytic regimen. Neutralising titration test is a commonly used classical assay for measuring anti-streptokinase antibodies and in this assay the ability of anti-streptokinase antibodies in patients' sera in preventing the lytic effect of streptokinase is assessd. As we showed previously the presence of r-tPA in the serum may interefere with the neutralising titration test, we investigated this interference in vitro. The level of neutralising anti-streptokinase antibodies in a serum sample with known levels of the antibodies were measured in absence and presence of increasing amount of r-tPA including therapeutic values. Increasing amount of r-tPA in vitro induced a sudden reduction in the measurable titre of anti-streptokinase antibody levels in a serum with elevated levels of anti-streptokinase antibodies. This effect of r-tPA, which is through activation of plasminogen has not been reported previously. 
We suggest this assay is unsuitable for clinical diagnosis of anti-streptokinase antibodies.</abstract>
    <web_url>https://ijaai.tums.ac.ir/index.php/ijaai/article/view/78</web_url>
    <pdf_url>https://ijaai.tums.ac.ir/index.php/ijaai/article/download/78/78</pdf_url>
  </Article>
</Articles>
